TMS Template standardizes the deliverable format for below Index.

TMS Feature Collect Index

For cables and conduits, use unique ID per run.

File

Feature Class

TMS Features (Code)

Coordinates collect point

Attribute Collect Information

TMS As-built Survey Data Template

Cables and Conduit

Fiber Optic Cable - Direct Buried (FO); Fiber Optic Cable in Conduit (FOCD); Communication Cable In Conduit [i.e. Loops, ramp meters, etc.] (CCIC); TMS Power Cable (ELIN)

Once every 50', at edge of pavement for roadway crossings, and at change in direction

1. Plan ID
2. Plan Sheet Number
3. Plan Print Note
4. Comments

Devices

Gate Arm (GA); Ped Gate (PG)

At Gate Support

Loop Detector (LOOP)

At Handhole Feeding Loop

Electric Meter (EMTR); Gas Meter (GMTR)

At Meter Roadway Side

Ramp Control Signal (RCS); Camera (CAM); Non-Intrusive Detector [Wavetronix] (NDET); Power Pole (EP)

At Pole Roadway Side

Dynamic Changeable Message Sign (DMS); Toll Beacon (TB); MnPass Toll Reader (TR); Fiber Optic Sign (SGNP)

At Sign Roadway Side

Structures

Shelter/Communications Hut (SHELTER); RTMC Cabinet (TMSCAB); Signal Cabinet (SIGCAB); Lighting Cabinet (LTGCAB); BD Splice Cabinet (TPED); Electrical Service Cabinet (EPED); Junction Box (JB)

At Structure Cable Entry Point

Generator (GEN); L.P. Tank (LPT)

At Structure Roadway Side

Fiber Optic Vault (CVLT); Handhole (CHH); Manhole (CMH)

At Structure Top Center

Example 1: Typical TMS improvement project

Example of a filled in TMS as-built survey data template

References